Chapter 5 Debugging and Test Run
ET/EP/EH Series Intelligent Flexible Driver Manual
- 59 -
5.3.5.8 [System Settings] status details
In the [System Settings] status, there are functions for setting date/time, program upgrade, and
waveform acquisition. In which, program upgrade can be performed via the operator to upgrade the
main control and IO board program; the waveform acquisition function can be enabled to achieve
waveform acquisition (the acquisition channel can be configured), automatically stored to the SD
card.
Press to return to the previous menu state.
5.4 Fault display
When the inverter has a fault, the fault code and name are displayed in the operator LCD screen. For
the fault code and name, see Table 5.5.
Table 5.5 Fault code and fault name
Error No.
Fault display
Error No.
Meaning
1
Module overcurrent
protection
3
Radiator overheating
7
Speed deviation
8
Busbar overvoltage
protection
9
Bus undervoltage
10
Output default phase
11
Motor overcurrent at low
velocity
12
Encoder fault
17
Overspeed in the same
direction
18
Overspeed in the reverse
direction
21
abc overcurrent
27
Output overcurrent
29
Abnormal bus fluctuation
30
Overspeed protection
31
Motor I2T current
32
Ground protection
34
External fault
37
Current sensor failure
39
Abnormal current sampling
42
Fault of brake short circuit
43
Communication error
44
Fault of drive board
communication
45
I2t instantaneous overcurrent
value
46
I2t valid overcurrent value
47
Analog input error
48
Fault of POWERID
49
Fault of wave-by-wave
current limiting
51
Running output current error
52
Abnormality of 15 V drive
voltage
53
Abnormality of braking
resistor wiring
54
Fault of power grid imbalance
55
Fault of power grid phase
sequence
56
Fault of power grid
undervoltage
57
Fault of power grid
overvoltage

Table of Contents