Chapter 7 Parameter Explanation
ET/EP/EH Series Intelligent Flexible Driver Manual
- 61 -
Chapter 6 Function parameter table
6.1 Description on function code parameter table
Short form fields
Summary Fields
Function code No.
The number of function code, e.g. P00.00
Function code
name
The name of the function code, explaining the code's function
Factory default
The set value after the function code restores the factory value (see P00.01)
Setting range
Minimum to maximum value allowed to be set by the function code
Unit
V: voltage; A: current; ℃: degrees; Ω: ohms; mH: millihen rpm: rotational speed %:
percentage; bps: baud rate; Hz, kHz: frequency; ms, s, min, h, kh: time; kW: power; /: no
unit, etc.
Attribute
○: the function code can be modified during operation; ×: the function code can only be
modified during shutdown; *: the function code is a read-only parameter and cannot be
modified
Function code
options
Function code parameter setting table
User settings
For user to record parameters
6.2 Brief table of function code parameters
6.2.1 Group P0X User parameters
Group P00 Password parameters
Function
code
Function code name
Factory
default
Setting range
Unit
Attribu
te
Option description
P00.00
Login password
0
0~65535
/
×
0: no password; others: login
password;
P00.01
Modify password
0
0~65535
/
×
0: no password; other:
password protection;
P01 group Customer usage parameters
6.2.2 Group P1X Control parameters
6.2.2.1 Group P10 Basic control parameters
Function
code
Function code name
Factory
default
Setting
range
Unit
Attrib
ute
Option description
P10.00
Control mode selection
0
0~6
/
×
0: GVC control
1: No PG vector control
2: PG Torque control
3: PG vector control
4: spare
5: No PG torque control
6: Voltage and current sources
P10.01
Operation modes
0
0~4
/
×
0: Two-wire 1; 1: Two-wire 2;
2: Three-wire 1; 3: Three-wire
2;
4: One wire
P10.02
Command channel
selection
0
0~6
/
×
0: Panel; 1: Terminal; 2:
Communication (Modbus); 3:
CAN(Spare); 4: DP(Spare); 5:
PLC; 6:SSI
P10.03
Speed channel 1
0
0~17
/
×
0: Panel setting speed

Table of Contents