Chapter 7 Parameter Explanation
Shanghai Sigriner STEP Electric Co., Ltd.
- 134 -
P81.04 sets local address; 0 is broadcast address; available addresses are 1 - 247; 248 - 255 are
reserved.
Function code
Name
Setting range
Factory setting
P81.07
Communication address formats
0~1
1
Select the communication address format, 0: Hexadecimal; 1: Decimal.
7.10.3 P82 group (Reserved parameter group)
Function code
Name
Setting range
Factory setting
P82.02
Custom status word 1
0~45
16
P82.03
Custom status word 2
0~45
13
P82.04
Custom status word 3
0~45
10
P82.05
Custom status word 4
0~45
18
P82.02 - P82.05 set the custom status:
0: Running status 1
1: Running status 2
2: Detection status
10: Output torque
13: Target frequency preset
14: Current running frequency
15: Feedback speed (Hz)
16: Feedback speed (rpm)
18: Output voltage valid value
19: Output current valid value
22: Total output power
23: Bus voltage
29: Output terminal status
31: Input terminal status
34: Analog input AI0
35: Analog input AI1
37: Output DA0
38: Output DA1
40: Recent fault number
43: Radiator temperature