Chapter 7 Parameter Explanation
Shanghai Sigriner STEP Electric Co., Ltd.
- 112 -
Detection frequency 3 upper
limit
Detection frequency 3 lower
limit
Detection frequency 4 upper
limit
Detection frequency 4 lower
limit
Detection frequency 3 corresponds to the terminal function code “38” and detection frequency 4
corresponds to terminal function code “39”.
7.5.3 P32 group Analog input
Parameter setting of analog input type:
0:0~10V; 2:0~20mA; 3:4mA~20mA
1: -10 V - 10 V (not supported)
P32.01 and P32.07 set the input function of analog AI:
0: No function
1: Target speed signal
2: Current speed signal
3: Torque signal
Input AI0 lower limit (%)
Input AI0 upper limit (%)
Input AI0 amplitude limit (V)
Input AI1 lower limit (%)
Input AI1 upper limit (%)
Input AI1 amplitude limit (V)
P32.02 - P32.05 and P32.08 - P32.11 respectively set the upper limit, lower limit, filtering time and
limiting of the two analog input ports.
The upper limit/lower limit combination is a proportionality coefficient.
By modifying the filtering time, the anti-interference ability of the terminal input can be improved,
because the analog input through the A0 and A1 terminals in the field application usually carries a
certain interference signal. However, the longer the filtering time, the longer the response delay of
the terminal action.