Chapter 7 Parameter Explanation
ET/EP/EH Series Intelligent Flexible Driver Manual
- 111 -
Set output terminal function to "10: speed detection 1", as shown in the following figure.
Figure 7-18 Speed detection 1
Set output terminal function to "11: speed detection 2", as shown in the following figure.
Figure 7-19 Speed detection 2
Function code
Name
Setting range
Factory setting
P31.24
Single running time arrival (h)
0~65535
2
When the run command of the inverter is given, after the single continuous running hours reaches
the value of P31.24, the indicator signal is output. The output indication signal can be activated by
defining the function code of the output terminal as "27".
Function code
Name
Setting range
Factory setting
P31.25
The cumulative running hours
are reached (h)
0~65535
8
When the inverter is powered on and the cumulative running hours reaches the value of P31.25, the
indicator signal is output. The output indication signal can be activated by defining the function code
of the output terminal as "26".