EasyManua.ls Logo

STEP ET Series - P62 Group Torque Control; P63 Compensating Torque Control; P7 X Group Enhanced Control; P70 Group Limit and Protection

Default Icon
200 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Chapter 7 Parameter Explanation
Shanghai Sigriner STEP Electric Co., Ltd.
- 74 -
P62 group Torque control
Function
code
Function code name
Factory
default
Setting
range
Unit
Attrib
ute
Option description
P62.00
Digital torque preset
0.0
0.0~400.0
%
×
P62.01
Torque direction
0
0~1
/
×
P62.02
Torque increase time
1.00
0.01~655.35
s
×
P62.03
Torque decrease time
1.00
0.01~655.35
s
×
P63 compensating torque control
Function
code
Function code name
Factory
default
Setting
range
Unit
Attrib
ute
Option description
P63.00
Compensating torque
direction
0
0~1
/
×
P63.01
Compensation gain
100.0
0.0~6553.5
%
×
P63.03
Preset torque
compensation
0.0
0.0~6344.0
%
×
P7X group Enhanced control
P70 group Limit and protection
Function
code
Function code name
Factory
default
Setting
range
Unit
Attrib
ute
Option description
P70.00
Upper frequency limit
50.00
0.00~655.35
Hz
×
0~maximum frequency
P70.01
Lower frequency limit
0.00
0.00~655.35
Hz
×
0~upper frequency limit
P70.02
ID preset limit
0.00
0.00~2.00
%
×
P70.03
ID limit gain
0
0~10000
/
×
P70.04
Output torque limit
150
0~250
%
×
P70.05
Accelerated
overcurrent threshold
160
0~200
%
×
P70.06
Decelerated
overvoltage threshold
750
540~800
V
×
P70.07
Overspeed protection
factor
120.00
0.00~655.35
%
×
P70.08
Special function
selection
6
0~65535
/
×
P70.10
PT signal channel
0
0~3
/
×
0: NC 1:PT1000/PT100
2: PTC high resistance 3: PTC
low resistance
P70.11
PT protection upper
threshold
120.0
0.0~1000.0
degree
×
P70.12
PT protection lower
threshold
0.0
0.0~1000.0
degree
×
P70.13
PT protection action
delay
3.0
0.0~10.0
s
×
P70.19
Bus undervoltage
threshold
380
0~540
V
×
P70.20
Power grid imbalance
threshold
50.0
10.0~200.0
%
×
P70.21
PWM detection delay
800
0~65535
ms
×
P70.23
Current-limiting
frequency reduction
threshold
120
50~200
%
×
Overcurrent frequency reduction
function
P70.24
Current limiting KP
0.001
0.000~65.53
/
×

Table of Contents