Chapter 7 Parameter Explanation
Shanghai Sigriner STEP Electric Co., Ltd.
- 80 -
Function
code
Function code name
Factory
default
Setting
range
Unit
Attrib
ute
Option description
P96.07
Built-in brake unit
current
Per
power
0~9999
A
*
0~9999
P96.08
Three-phase current
balance coefficient
1.000
0.900~1.200
*
P96.09
Rated current (480 V)
Per
power
/
A
*
P96.10
Light load current (480
V)
Per
power
/
A
*
P96.15
Software build
6
/
/
*
P96.16
Special parameters
90
1~65535
/
*
POWERID lock
P96.17
Sensor factor
correction
2
0~3
/
*
P96.18
Voltage correction
coefficient
100.0
90.0~110.0
%
*
Bus sampling correction
P96.19
Current correction
coefficient
100.0
50.0~200.0
%
*
Current sampling correction
P96.20
Light load and heavy
load selection
0
0~2
/
*
0: Light load (standard)
1: Heavy load (standard)
2: Light load (ES)

Table of Contents