Operation & Service Manual (VA) 72 ST1175
Output power
supply fault
Defective power
supply to outputs.
Set the main switch(es) to
OFF.
Check and replace fuse F2
(3.15A) if required. Also
check the thermal relay and
reset it if required. Turn on
the control box again using
the standard procedure. If
the fault occurs again,
contact the technical service.
Short circuit on the
PCB.
Allow damp box to dry.
Replace PCB if the fault
persists.
Turn OFF and ON on the
main switch(s) and press the
[SELECT] button to ensure
the system can be used
again. Replace the PCB if
required.
8.4 Faults
The following troubleshooting guide can be used to help localize faults. If in doubt,
the user should contact the technical service.
In the event of malfunctions other than those described here, always consult the
technical service.