Place a container in front of the coolant
drain plug ( as the arrow shows ).
Remove the radiator cap(1).
Unplug the coolant drain plug of the radiator
and then drain coolant.
After completing coolant drain, connect the
coolant drain plug again.
Drain the coolant from the coolant supple-
mentary tank(2) and cleanse the tank.
Fill the radiator inlet with water and install
radiator cap(1).
NOTE
Slowly pour coolant in to let the air be dis-
charged from radiator and press the hose con-
nected to it to discharge the air inside.
Start the engine to let the cooling fan rotate
2 or 3 times. When the engine is warmed
up, increase the engine RPM two or three
times.
Stop engine and wait until engine is cooled.
Remove the radiator drain plug and drain
water.
Repeat the above mentioned processes
from 1 to 8 until the drained water becomes
clear.
Press the hose connected to the radiator to
discharge the air from inside of the radiator
and slowly fill the radiator with the coolant
Maintenance
5
Maintenance service
122 60068011601 EN - 09/2020

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Still RCD25 and is the answer not in the manual?

Still RCD25 Specifications

General IconGeneral
BrandStill
ModelRCD25
CategoryTrucks
LanguageEnglish

Related product manuals