EasyManua.ls Logo

STYLE 350 - Installation of the Machine; Environment requirements; Foundation; Fuse specifications electrical supply

STYLE 350
44 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Machine manual STYLE 350 – 510 V4.9
18
4 Installation of the machine
This chapter gives information about installation of the machine. Check if the machine is supplied with all parts
which are ordered. In case of missing parts or wrong parts please contact your dealer by using the claim form.
4.1 Environment requirements
Because of the design of the current machine it not recommended to use the machine in an environment where
electric and metal sparks are prohibited.
Environmental temperature ranging from 5°C - 30°C.
Environment free of poisonous vapors, gases and salt.
Prevent abnormal vibrations of foundation.
Prevent direct sunlight or heat rays which can greatly influence the machine working temperature.
The maximum fluctuation of the nominal frequency should be within 1% of the source frequency.
The maximum fluctuation of the nominal voltage should be within 1% of the source voltage.
It is prohibited to use the machine in an environment where possible risk of explosions are present
4.2 Foundation
Regarding foundation and the position of the levelling bolts of the machine. Because of tolerances of the casting of
the machine frame, it is recommended to measure the actual machine dimensions when it is on its location.
Consult a specialized building constructor for dimensions and installation of machine foundation.
4.3 Preparation for positioning the machine
4.3.1 Fuse specifications electrical supply
The machine should be connected using a 400VAC / 3 phase /50 Hz electrical connection CEE-Form connecting
socket. The machine should be grounded properly according to the local requirements and regulations. When
questions arise, please contact your dealer.
Other specifications and connection guidelines are found in the machine preparation document.
Fuse STYLE 350 - 510
Main motor [kW]
5,5
7,5
11
Max use [kW]
12
14
16
Fuse [A]
25
25
32
The machine should have a dedicated and switchable 400 volt electrical source. The
user of the machine is responsible for the electrical connection and installation
according to the local requirements and regulations.
4.3.2 Compressed air
For a standard machine with machine options no compressed air is needed for operating the machine.

Table of Contents