84 Sun Fire X4170, X4270, and X4275 Servers Installation Guide • December 2009
3. Accept the certificate when prompted.
4. Enter your user name (root) and password (changeme).
5. Select the Configuration tab and then the Network tab.
6. Set configurations, such as IP configuration, as required.
a. Do one of the following:
■ If DHCP is required, select the Enable DHCP check box.
■ If STATIC is required, clear the Enable DHCP check box, and manually set
all IP information.
b. If you manually change the IP address, you must manually change the
subnet mask, because the subnet mask changes according to the IP address
class.
7. Save your settings.
8. Log out of ILOM.
9. If the IP address changes, you must reconnect to ILOM using the newly
assigned IP address, because the current session will become unresponsive.
For detailed information on using ILOM, see the Sun Integrated Lights Out
Manager 2.0 User’s Guide (820-1188).
Applying Main Power to the Server for
the First Time
When you are ready to install a supported operating system, you can apply main
power to the server.
▼ Apply Main Power to the Server
To turn on main power to the server for the first time, following these steps:
1. Verify that the power cord has been connected and that standby power is on.
In standby power mode, the Power/OK LED on the front panel blinks. See
FIGURE 4-3, FIGURE 4-4,orFIGURE 4-5.
2. Verify that you are connected to the server through the serial management (SER
MGT) port; perform the following sub-steps: