62 Sun Fire X4170, X4270, and X4275 Servers Installation Guide December 2009
Caution Always load equipment into a rack from the bottom up so that it will not
become top-heavy and tip over. Extend your rack’s anti-tip bar to prevent the rack
from tipping during equipment installation.
Install Server Into the Slide-Rail Assemblies
1. Push the slide-rails into the slide-rail assemblies in the rack as far as possible.
2. Raise the server so that the rear ends of the mounting brackets are aligned with
the slide-rail assemblies that are mounted in the equipment rack (see
FIGURE 3-6).
3. Insert the mounting brackets into the slide-rails, then push the server into the
rack until the mounting brackets encounter the slide-rail stops (approximately
12 inches, or 30 cm).