80
Category
3rd2nd1st
Data Field
Cmd FieldExplanation
Input
Port
Check
WaitPort
Sequence
Control
Wait until
the port
signal detected
BrChkPort
(Check the
port and
branch
the given
address)
Branch
GenSeq
StartSeq
EndSeq
Button A 0(Input Port No
Button B 1
Switch 1/4 stitch 2
Switch 2/4 stitch 3
Switch 3/4 stitch 4
Switch 4/4 stitch 5
Left Solenoid Switch 6
Right Solenoid Switch 7
Pressor Foot Lift Switch 8
Counter Switch F0H 9
Button 1/2 switch on P/U Box 10
Safety Switch 11
Edge Sensor 12
Trimming Disable Switch 13
Roller lift Switch 14
N-AUTO Switch 15
Pedal Start Input 16
Pedal Pressor-Foot Input 17
Pedal Thread Trimming Input 18
External Input 19
Button A 0 (Port No 0~64 (address
Button B 1 0~64
Switch 1/4 stitch 2 0~64
Switch 2/4 stitch 3 0~64
Switch 3/4 stitch 4 0~64
Switch 4/4 stitch 5 0~64
Left Solenoid Switch 6 0~64
Right Solenoid Switch 7 0~64
t Switch 8 0~64
Counter Switch F1H 9 0~64
Button 1/2 switch on P/U Box 10 0~64
Safety Switch 11 0~64
Edge Sensor 12 0~64
Trimming Disable Switch 13 0~64
Roller lift Switch 14 0~64
N-AUTO Switch 15 0~64
Pedal Start Input 16 0~64
Pedal Pressor-Foot Input 17 0~64
Pedal Thread Trimming Input 18 0~64
External Input 19 0~64
Branch to given address F2H 0~64 (Address
General Trimming Sequence F3H
Start of the sequence 80H
End of the sequence 00H
Caution
[ Caution ]
•Every the conditional Branch is made to the appropriate number when it is on "No(False)"
•When makingthe sequence program, please check and use its function because the wrong sequence program can
cause the mechanical trouble and the physical damage.