00-3 Precautions:
When connecting meter probe from the terminal side
of the coupler (where connection from harness side
not being possible), use extra care not to force and
cause the male terminal to bend or the female
terminal to open. Connect the probe as shown to
avoid opening of female terminal. Never push in the
probe where male terminal is supposed to fit.
Check the male connector for bend and female
connector for excessive opening. Also check the
coupler for locking (looseness), corrosion, dust, etc.
Clamp
Clamp the wire harness at such positions as indicated
in “Wiring Harness Routing Diagram: in Section
9A”.
Bend the clamp properly so that the wire harness is
clamped securely.
In clamping the wire harness, use care not to allow it
to hang down.
Do not use wire or any other substitute for the band
type clamp.
Fuse
When a fuse blows, always investigate the cause to
correct it and then replace the fuse.
Do not use a fuse of different capacity.
Do not use wire or any other substitute for the fuse.
Switch
Never apply grease material to switch contact points to
prevent damage.
ECM / EPS control unit / EPS body assembly /
Various sensors
Since each component is a high-precision part, great
care should be taken not to apply any severe impacts
during removal and installation.
3. Coupler 4. Probe “A”: Where male terminal fits
3
4
4
“A”
I649G1000030-02
CORRECT INCORRECT
I718H1000001-02
I649G1000001-02
I931H1000001-02
I931H1000003-02