Edit Equipment (cont’d)
The parameters which can be entered in the <spec_block> are listed below. For any specific
<aid> entered in a command, only certain parameters are valid. For each valid parameter,
choose the appropriate value of “a” from the “Value” column. When entering multiple
parameters, separate the parameters with commas.
Aid Parameter Value Description
TS3100 ROFREQ=a a=5 or 10 Frequency for both remote oscillator inputs in
MHz
TOD=a a=CISCO Serial TOD message sent in CISCO format
a=NTP4 Serial TOD message sent in NTP4 format
a=NONE No serial message sent
ALMCOND=a a=ALW Alarm conditioning for E1, TOD, and IRIG-B
outputs is enabled
a=INH Alarm conditioning for E1, TOD, and IRIG-B,
outputs is disabled
IPNE=a.b.c.d
(See Note 1)
a = 0 to 255 IP address of this TimeSource 3100
(command must be sent from COM1, COM2,
or Craft port to set this parameter)
b = 0 to 255
c = 0 to 255
d = 0 to 255
IPSUBNET=a.b.c.d
(See Note 1)
a = 0 to 255 Subnet mask for this TimeSource 3100
(command must be sent from COM1, COM2,
or Craft port to set this parameter)
b = 0 to 255
c = 0 to 255
d = 0 to 255
IPGATE=a.b.c.d
(See Note 1)
a = 0 to 255 Default gateway IP address for this
TimeSource 3100 (command must be sent
from COM1, COM2, or Craft port to set this
parameter)
b = 0 to 255
c = 0 to 255
d = 0 to 255