SSSSSSSSSSS SSSS S SSSSS SSSSSSS S SSS S SSSSS S
4
136 TimeSource 3100
TL1 Reference
097-72020-01 Issue 9: November 2003
TS3100
(cont’d)
IPEM1=a.b.c.d
(See Note 1)
a = 0 to 255 IP address of primary element manager (port
5550 connects to this element manager to
send autonomous messages, disconnects
when transmit is complete)
b = 0 to 255
c = 0 to 255
d = 0 to 255
IPEM1PORT=a
(See Notes 1, 2, 3)
a = 0 to
65535
Port address of primary element manager
(port for IPEM1 address)
IPEM2=a.b.c.d
(See Note 1)
a = 0 to 255 IP address of alternate element manager
(port 5550 connects to this element manager
to send autonomous messages, disconnects
when transmit is complete)
b = 0 to 255
c = 0 to 255
d = 0 to 255
IPEM2PORT=a
(See Notes 1, 2, 3)
a = 0 to
65535
Port address of alternate element manager
(port for IPEM2 address)
IPINACT=a
(See Note 1)
1 = 0 to
10000
Port 5550 closes the connection to the
Element Manager if no autonomous message
are sent during this number of 100-ms units
(0 to 10000, where 0 deactivates the timer;
for example, 100 = 10 s)
ALARM=x x=HOLD-
OVER
HOLDOVER alarm
x=GPS GPS alarm
SPAN
A & B
ALARM=x x = LOS LOS alarm
x = AIS AIS alarm
x = ERROR ERROR alarm
RO
A & B
ALARM=x x = LOS LOS alarm
x = ERROR ERROR alarm
TS3100,
SPAN A&B,
RO A&B
TIME=x x = HH-MM Hour (00-999) and minute (00-59) time to
escalate alarm
x = 0 No alarm escalation
SEVERITY1=x
(See Note 4)
x = CR Severity of initial alarm prior to escalation
x = MJ
x = MN
x = EV
x = NA