TimeSource 3100 153
TL1 Reference
097-72020-01 Issue 9: November 2003
2
5
3
SSSSSSSSSSSS SSSS S SSSSS SSSS SSS S SSS S SSSSS
44
Retrieve Communication (cont’d)
Parameter Value Parameter Description
AUTOLOGOFF=a a = 1 to 255 Inactive minutes until the unit logs off the
user, keeping the connection open
a = 0 Autologoff is disabled
SWCONTROL=a a = ALW XON/XOFF flow control is enabled
a = INH XON/XOFF flow control is not enabled
HWCONTROL=a a = ALW Serial port CTS/RTS flow control is
enabled
a = INH Serial port CTS/RTS flow control is not
enabled
BAUD=a a = 115 Serial port baud rate is 115 kbaud
a = 57.6 Serial port baud rate is 57.6 kbaud
a = 38.4 Serial port baud rate is 38.4 kbaud
a = 19.2 Serial port baud rate is 19.2 kbaud
a = 9600 Serial port baud rate is 9600 baud
a = 4800 Serial port baud rate is 4800 baud
a = 2400 Serial port baud rate is 2400 baud
PARITY=a a = EVEN Even parity bit is enabled
a = ODD Odd parity bit is enabled
a = NONE Parity bit is disabled
STOP=a a = 1 1 stop bit
a = 2 2 stop bits

Table of Contents

Other manuals for Symmetricom TimeSource 3100

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Symmetricom TimeSource 3100 and is the answer not in the manual?

Symmetricom TimeSource 3100 Specifications

General IconGeneral
BrandSymmetricom
ModelTimeSource 3100
CategoryGPS
LanguageEnglish

Related product manuals