1
TimeSource 3100 181
TL1 Reference
097-72020-01 Issue 9: November 2003
2
5
3
SSSSSSSSSSSS SSSS S SSSSS SSSS SSS S SSS S SSSSS
44
Retrieve Performance Monitoring (cont’d)
PHASE1S Response Example (cont’d):
"SPAN-A:PHASE1S,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,
0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0
,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,
0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0
,0,0,0,0,0,0,0,0,0,0,0,NA,,,,2000-10-13,12-58-20"
/* LINK: 5001, CMD: RTRV-PM-EQPT::SPAN-A:C:: PHASE1S,,,,, */
;
PHASE1M Response Format:
<sid> <date> <time>
M <ctag>COMPLD
"SPAN-a:PHASE1M,<monval>,<monval>,
<monval>,<monval>,<monval>,<monval>,
...
...
...
<monval>,<monval>,<monval>,<monval>,
<vldty>,,,,<mondat>,<montm>"
/*LINK:<link>,CMD:<command>*/
;
Note: PHASE1M Data types:
• The TimeSource 3100 collects a full 7 days of 1 minute phase data.
• The 1 minute phase data is displayed in 1 hour groups. Each request for 1 minute
phase is synchronized to the hour.
• Any mondat/montm combination outside of the past 7 day window is denied. Any
time increment may be entered. The system rounds the value to the nearest hour, i.e.,
the minute and second field of the montm is ignored.
• The first value (monval) is the oldest value in the range selected. For example, if
montm = 8:45:32, the first monval will exceed time 8:00:00 followed by the value at
8:01:00, etc.