182 TimeSource 3100
TL1 Reference
097-72020-01 Issue 9: November 2003
Retrieve Performance Monitoring (cont’d)
PHASE1M Response Example:
TS3100-2009 2000-05-25 11:01:58
M G COMPLD
"SPAN-A:PHASE1M,0,0,0,0,0,0,0,0,0,0,0,0,
0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0
,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,
0,0,COMPL,,,,,2000-05-25,100-00"
/*LINK:5002,CMD:RTRV-PM-EQPT::
SPAN-A:G::PHASE1M*/
;
Parameter Value Item Addressed
SPAN-a a = A E1 span A input
a = B E1 span B input
PHASE1M — Phase 1M monitored type, which
shows 1 min. phase data in 1 h
groups of data
<monval> Oldest value in
the range
selected from the
<montm> value
assigned in the
command
Absolute monitored phase value
<vldty> COMPL Data is valid
NA Data is not valid
MONDAT=a-b a = 1 to 12 Monitor date, month of the year
b = 1 to 31 Monitor date, day of the month
MONTM=a-b a = 0 to 23 Monitor time, hour of the day
b = 0 to 59 Monitor time, minute of the hour