52 Installation TB7100 Installation and Operation Manual
© Tait Electronics Limited December 2005
4.8.6 Cabling
We recommend that you route all cables to and from the base station along
the side of the cabinet so the cooling airflow is not restricted.
Cables should be well supported so that the connectors or terminals on the
base station and on the ends of the cables do not have to support the full
weight of the cables.
Cables must be routed so that they do not restrict the air outlets at the rear
of the base station.
4.8.7 Accessories
The base station can use the following accessories:
■ T809-10-87xx power supply
■ TBBA03-01 wall mounting kit
■
TBBA03-02 duplexer kit
(mechanical configuration without internal AC power supply unit)
■ TBBA03-03 duplexer kit
(mechanical configuration with internal AC power supply unit)
■ TMAA02-01 fist microphone.