MultiLevel Instruction Manual Quick Start
3.1. Operating error
Unable to leave operating mode.
• If you are in the NoMix "Menu", for example, and press "Discharge" or "Load-
ing" for MultiLevel, and are then unable to navigate to or leave the mode in
question, then please check the NoMix device to establish whether it is in the
type in MultiLevel if both devices are in the same mode.
• This situation always occurs if MultiLevel and NoMix have not synchronized
their modes.
No status screen after switching on.
• If the Status screen fails to appear after switching on and an incomplete dis-
Permissible calibration slope exceeded / underrun.
• A calibrated discharge cannot be carried out if the slope is outside of the
calibration limit (± 5).
The following error message is issued:
„Uncalibrated discharge2! Longitudinal slope not within calibration limits!“
You must acknowledge this error message by pressing the <F1> key = OK.
Generally permissible slope exceeded / underrun.
• Measured discharge is not possible if the slope is outside the generally
permissible slope (± 8).
The following error message is issued:
„Unmeasured discharge 3! Slope outside of the slope table“
You must acknowledge this error message by pressing the <F1> key = OK.