MultiLevel Instruction Manual Technical Data
12 – Technical Data
12.1. System Data
Approvals:
Examined after OIML R80 -1
Explosion protection: ATEX II 2 G EEx m ia e IIB T4
Measuring range: 40 to 4.000 mm
Measuring accuracy: ± 0,1 mm
Pitch measurement (dip stick): Up to ±5°: calibrated delivery
±5° to ±8°: measured delivery
over ±8°: unmeasured delivery
Communication: intern: CAN bus and TAG Protocol
extern: EMIS Interface
(RS232, DOK-411, E7 Protocol)
Measuring medium viscosity range:
Operating temperature: -20 °C to +60 °C
Power supply: 24 VDC (15-30V) < 30 W
Functional reliability: The following guidelines are met
DIN 26053
Secured measurement of tank vehicles for the
delivery of heating oil, diesel fuel and biodiesel
to consumers
12.1.1. Main Unit Display / MLMAINDISP2
Power supply: 24V DC nominal voltage (operating range from
10....30V DC ) under 30 Watt,
from built-in battery of corresponding vehicle,
protected against overvoltage (>50V)
CAN bus circuit, external:
CAN bus circuit, internal:
Printer circuit:
EC-Type Examination
Certicate Number:
TÜV 03 ATEX 2022
12.1.2. Level Gauge Interface Type LLGIF
Power supply: 24V DC nominal voltage
(operating range from 15....30V DC ) under 30
Watt, from built-in battery of corresponding vehicle,
protected against overvoltage (>50V)
Data circuit:
Level gauge circuits: In intrinsically safe level of protection: II 2 G EEx ia
IIB with following maximum values:
UO = 16,8 V
IO = 161 mA
PO = 0,68 W
Characteristic: linear
Max. permissible external inductance
LO = 5,5 mH
Max. permissible external capacitance
CO = 2,29 µF