No. Name K Factory
Setting
Meaning
3.1.4.2.1.3 Auto-Adjust M YES Activates / deactivates the automatic adjustment of the stop point for volume
preset
3.1.4.3 Loading
3.1.4.3.1 Valve Control M manual Control of the bottom valves during loading
- automatic Bottom valves are opened automatically
- manual Bottom valves must be opened manually
3.1.4.3.2 Loadplan Query M NO Query of Loading plan at beginning of Loading

- YES Query at beginning of loading
- NO No query
Parameter 31411 (change Lplan) also applies!
3.1.4.3.3 Loading
measurement
M NO Temperature-compensated Measurement during Loading
- YES Measurement incl. Printing
- NO No Measurement, no Printing
󰀨
3.1.4.7 Help screens
M See separate table
3.1.5 W&M restrictions
3.1.5.1 Seal password E 12345678 Password for electronic W & M seal
3.1.5.4 Slopes
3.1.5.4.1 Min. pitch slope E -5.0° Min. pitch slope for calibrated delivery
3.1.5.4.2 Max. pitch slope E +5.0° Max. pitch slope for calibrated delivery
3.1.5.4.3 Min. roll slope E -5.0° Min. roll slope for calibrated delivery
3.1.5.4.4 Max. roll slope E +5.0° Max. roll slope for calibrated delivery
3.1.5.4.5 Sens. Correct.Pitch E 0.0 󰀨

3.1.5.4.6 Sens. Correct.Roll E 0.0 󰀨

3.1.5.4.7
Inst. Correct.Pitch E 0.0 󰀨
3.1.5.4.8
Inst. Correct.Roll E 0.0 󰀨
3.1.5.5 Receipt printing
3.1.5.5.1 Minimum form E 101, 103,
500, 503,
504
Minimum requirement of the weights and measures authority for delivery re-

3.1.5.5.2 Decimal Separator E Comma Decimal separator: comma ’,’ or point ’.’
3.1.5.6 Device info
3.1.5.6.1 Device number E - ? - The device number (rating plate, see housing of operating device) must be
entered in this parameter.
3.1.5.6.2 Tank Number E - ? - Serial number of the tank
3.1.5.6.3 Truck-ID E - ? - e.g. registration number of the tank truck
3.2 Printer settings
3.2.1 Printer selection M DR-295 Selection of the printer used:
- DR-295
- DR-298
- DR-220
- ESC/P
- ESC/P2
- ASCII

3.2.2 Interface
3.2.2.1 Port Number M COM1 Selection of the interface to be employed:
COM1 1. serial interface (RS232/RS485)
COM2 2. serial interface (RS232)
3.2.2.2 Interface Type M RS232 Switching between RS232 and RS485 (only for COM1)
3.2.2.3 Transfer Rate M 9600 Transmission speed