STEPRACE: Service & Maintenance Manual - rev. 1.2
Page 7.15
7.12. DISASSEMBLING THE PEDALS AND PEDAL GROUP
Figure 7.12-1
Turn off the machine and unplug the mains lead
from the wall outlet.
1. Select stepping mode B (dependent stepping
motion).
Working from both sides:
2. Remove the protective cap a.
3. Back off the screw underneath the cap using
17-mm wrench.
Figure 7.12-2
To disassemble the bracket:
4. Back off the 4 nuts b which fix the bracket c
to the PEDAL, using a 13-mm wrench.
5. Remove the bracket c.
Figure 7.12-3
To disassemble only the PEDAL:
6. Rotate the PEDAL.
7. Back off the screw d which fixes the PEDAL
GROUP pivot to the lever, using a 6-mm hex
T wrench.
Continued on the following page