UNICA EVOLUTION: Service & Maintenance Manual - rev. 1.1
Page 10.22
10.7. CONFIGURATION: CALIBRATION
This procedure calibrates the value shown on the display so that it matches the selected weight. To
access the procedure select the CALIBRATION item from the main configuration menu. The
display shows:
CALIBRATION
SELECT THE LAST
WEIGHT STACK PLATE
Position the selector pin on the last plate of the weight stack, as prompted by the message, then
press OK: after sounding a beep, the software reverts to stand by mode.
If the procedure is completed successfully, the weight value shown on the display should match that
of the selected weight stack plate.
ATTENTION: calibration is necessary if the selector pin position is changed when the
machine is switched off, causing the display to show a different weight value from that
actually selected by the pin.