GPS7 GPS Synchronization and Timecode module remote commands
Sets timecode s
ource. Disable shuts off the timecode output. TOD sets the
time of day clock as the source. Counter sets the timecode source to the
program counter.
:OUTPut[1/2/3]:TIMECode:SO URce?
Returns the current timecode source setting.
:OUTPut[1/2/3]:TIMECode:OF FSet <NR1>,<NR1>,<NR1>,<NR1>
Sets the timecode offset in hours, minutes, seconds, and frames
(HH:MM:SS:FF).
:OUTPut[1/2/3]:TIMECode:VI Tc[1/2]:STATe 0 | 1
Enables or disables the insertion of a VITC. You can enable two timecodes.
Setting the state to 1 enables the timecode. Setting the state to 0 disables
the timecode.
:OUTPut[1/2/3]:TIMECode:VI Tc[1/2]:STATe?
Returns the VITC insertion state.
:OUTPut[1/2/3]:TIMECode:LI Ne
Sets the line number on which the VITC is located. For NTSC output, the line
number range is 10-20. For PA L output, the line number range is 6-22. For
HD output, the line number range is 7-40.
:OUTPut[1/2/3]:TIMECode:LI Ne?
Returns the line number o n which the VITC is located.
:OUTPut[1/2/3]:DROPf0|1
Enables or disables the us e o f Drop Frame timecode.
:OUTPut[1/2/3]:DROPf?
Returns the Drop Frame timecode state. A setting of 0 means drop frame
timecode is not used. A setting of 1 means drop frame timecode is used.
:OUTPut[2]:LLOSs:STATe 0 | 1
Sets the Black 2 signal to go to 0 V DC if a Loss of Lock condition occurs.
Using 1 enables the function. Using 0 means the Black 2 signal will not
change due to Loss of Lock.
:OUTPut[2]:LLOSs:STATe?
Returns the setting for Black 2 to go to 0 V DC on Loss of Lock.
:OUTPut4:LTC[1/2/3/4]:SOUR ce DISable | TOD | PCOUnter
Sets linear timecode output source. DISable shuts off the timecode output.
TOD sets the time of day clock as the source. PCOUnter sets the timecode
source to the program counter.
Draft