HD3G7 3 Gb/s SDI Video Generator module remote commands
Sets the alpha c
hannel signal. The choices are COPY_YG (fills the alpha
channel with Y or G data from the input signal), FF_0P (0% Flat Field),
FF_10P (10% Flat field), FF_20P (20% Flat field), FF_30P (30% Flat field),
FF_40P (40% Flat field), FF_50P (50% Flat field), FF_60P (60% Flat field),
FF_70P (70% Flat field), FF_80P (80% Flat field), FF_90P (90% Flat field),
and FF_100P (100% Flat field).
:OUTPut1:ALPHa?
Returns the current alpha channel signal.
:OUTPut1:ANC:OUTMode <DIS|CO NT|SING>
Sets the ancillary payload output mode. The choices are DIS (disable), CONT
(continuous), and SING (single packet).
:OUTPut1:ANC:OUTMode
Returns
the ancillary payload output mode setting.
:OUTPut1:ANC:PARIty <MAN|AUT O>
Sets the ancillary payload parity. The choices are AUTO (automatic) and
MAN (manual).
:OUTPut1:ANC:PARIty?
Returns the ancillary payload parity setting.
:OUTPut1:ANC:LINe <NR1>,<NR1 >
Sets the line on which the ancillary payload starts. Two values are required;
the first value is for the Field 1 line number and the second value is for the
Field 2 line number. If only a single value is sent, an error will be returned.
:OUTPut1:ANC:LINe?
Returns the line o n which the ancillary payload starts.
:
OUTPut1:ANC:SAMPle <NR1>
Sets the ancillary payload sample start location. The default value is 1928.
:OUTPut1:ANC:SAMPle?
Returns the ancillary payload sample start setting.
:OUTPut1:ANC:DID <HEX>
Sets the ancillary payload Data Identifier. The data identifier range is from 1
to 255 (FF hex). The Data Identifier should be followed by either a Secondary
Data Identifier (SDID) or a Data Block Number (DBN) followed by a Data
Count (DC). The Data Count value is followed by User Data Words (UDW),
which are followed by a checksum value.
Draft
104 TG8000 Multiformat Test Signal Generator Programmer Manual