HD3G7 3 Gb/s SDI Video Generator module remote commands
You can send bot
h 8-bit and 1 0-bit words. A query returns an 8-bit or 10-bit
word depending on the ANC:PARITY setting in the instrument. If the you
send 10-bit word when the Parity is Auto(8-bit), the instrument masks the
value. The DID value should be in Hex ( preceded by #H as shown in below).
:OUTP1:ANC:DID #HFE
:OUTP1:ANC:DID #H2FF
:OUTPut1:ANC:DID?
Returns the ancillary payload Data Identifier.
:OUTPut1:ANC:SDID <HEX>
Sets the ancillary payload Secondary Data Identifier. The Secondary Data
Identifier is valid only if the DID is less than 80 hex.
You can send both 8-bit and 10-bit words. A query returns an 8-bit o r 10-bit
word depending on the ANC:PARITY setting in the instr
ument. If you send a
10-bit word when the Parity is Auto (8-bit), the instrument masks the value.
The SDID value should be in Hex (preceded by #H, as shown in below).
:OUTP1:ANC:SDID #HFE
:OUTP1:ANC:SDID #H2FF
:OUTPut1:ANC:SDID?
Returns the ancillary payload Secondary Data Identifier.
:OUTPut1:ANC:DBN <HEX>
Sets the ancillary payload Data B lock Number.
You can send both 8-bit and 10-bit words. A query returns an 8-bit o r 10-bit
word depending on the ANC:PARITY setting in the instrument. If you send a
10-bit word when the Parity is Auto (8-bit), the instrument masks the value.
TheDBNvalueshouldbeinHex(precededby#H,asshowninbelow).
:OUTP1:ANC:DBN #HFE
:OUTP1:ANC:DBN #H2FF
:OUTPut1:ANC:DBN?
Returns the ancillary payload Data Block Number.
:OUTPut1:ANC:DC <NR1> {0-254}
Sets the ancillary payload Data Count. The DC value determines how many
payload data (UDW) can be set.
:OUTPut1:ANC:DC?
Returns the ancillary payload Data Count. The data count indicates how many
user data words should follow.
Draft