HD3G7 3 Gb/s SDI Video Generator module remote commands
ZP_VSINE Vertical Sine Zone Plate
ZP_VSWEEP Vertical Sweep Zone Plate
ZP_1_CUSTOM Custom1 Zone P late
ZP_2_CUSTOM Custom2 Zone P late
:OUTPut1:SYNThesizer:SIGNa l?
Returns the current HD test signal.
:OUTPut1:SYNThesizer:SIGNa l:LIST?
Returns all available signals by name. The information of each signal is
separatedbycolon":".
:OUTPut1:SYNThesizer:SIGNa l:COUNt?
Returns how many parametric signals are present in the instrument.
:OUTPut1:SYNThesizer:SIGNa l:LOAD
Loads a parametric signal with specified signal name. A list of all available
signals is found by using the SIGNAL:LIST? query.
:OUTPut1:SYNThesizer:SIGNa l:LOAD
Returns the current parametric signal.
:OUTPut1:TIMECode:SOURce TOD| PCOUnter
Sets time code source. TOD sets the time of day clock as the source (available
only if a GPS7 module is installed in the TG8000). PCounter sets the time
code source to the program counter (always available).
:OUTPut1:TIMECode:SOURce?
Returns the timecode source setting.
:OUTPut1:TIMECode:OFFSet <NR1 >,<NR1>,<NR1>,<NR1>
(HH:MM:SS:FF)
Sets the time code offset in hours, minutes, seconds, and frames
(HH:MM:SS:FF).
:OUTPut1:TIMECode:OFFSet?
Returns the time code offset in hours, minutes, seconds, and frames
(HH:MM:SS:FF). This setting is valid only if a GPS7 module is present.
:OUTPut1:TIMECode:DROP:STA Te <0|1>
Enables or d isables the use of Drop Frame timecode (for non-integer frame
rate only). A setting of 0 means drop frame timecode is not used. A setting of
1 means drop frame timecode is used.
:OUTPut1:TIMECode:DROP:STA Te?
Draft