DVG7 Digital Video Generator module remote commands
Returns the cur
rent sample bits of a s pecic embedded audio group for the
selected outputs. The <n> in the command represents the output connector
type. "1" represents the SIGNAL connectors and "2" represents the optional
BLACK connectors. The <m> in the command represents the group number
and you can use any channel number from 1 through 4.
:OUTPut<n>:EAUDio:GROup<m >:SAMPLIng FRAMe|NOFRame|ASYNc
Sets the sampling alignment status bits in the audio signal of a specic
embedded audio group for the selected outputs. The <n> in the command
represents the output connector type. "1" represents the SIGNAL connectors
and "2" represents the optional BLACK connectors. The <m> in the
command represents the group number and you can use any channel number
from 1 through 4.
:OUTPut<n>:EAUDio:GROup<m >:SAMPLIng?
Returns the current sampling alignment status bits settings of a specic
embedded audio group for the selected outputs. The <n> in the command
represents the output connector type. "1" represents the SIGNAL connectors
and "2" represents the optional BLACK connectors. The <m> in the
command represents the group number and you can use any channel number
from 1 through 4.
:OUTPut1:LOGO:STATe ON|OFF
Turns the logo overlay display on the video signal on o r off. You can also use
1or0insteadofONorOFF.
:OUTPut1:LOGO:STATe?
Returns the current logo overlay state.
:OUTP
ut1:LOGO:POSition:HORizonta l <numeric_value>
Sets the horizontal position of the logo as it appears on the active signal.
The unit is percent of active picture width. You c an set the position from
-100% to 0% in 0.1% steps. You can also use MIN, MAX, or DEF instead of
a numeric value.
:OUTPut1:LOGO:POSition:HO Rizontal?
Returns the current horizontal position of the logo.
:OUTPut1:LOGO:POSition:VE RTical <numeric_value>
Sets the vertical position of the logo as it appears on the active signal. The
unit is percent of active picture height. You can set the position from -100%
to 0% in 0.1% steps. You can also use MIN, M AX, or DEF instead of a
numeric value.
:OUTPut1:LOGO:POSition:VE RTical?
Returns the current vertical position o f the logo.
Draft
70 TG8000 Multiformat Test Signal Generator Programmer Manual

Table of Contents

Other manuals for Tektronix TG8000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Tektronix TG8000 and is the answer not in the manual?

Tektronix TG8000 Specifications

General IconGeneral
BrandTektronix
ModelTG8000
CategoryPortable Generator
LanguageEnglish

Related product manuals