Category | Purge and Trap Concentrator |
---|---|
Applications | Volatile Organic Compounds (VOCs) analysis |
Trap Heating Rate | 40°C/sec |
Desorb Flow Rate | Up to 500 mL/min |
Moisture Control | Yes |
Automation | Yes |
Heating Time | Variable |
Agitation | Yes |
Cooling | Yes |
Dimensions | Varies by model |
Weight | Approximately 25 kg |
Power Requirements | Varies by model |
Crucial safety and operational guidelines before using the Versa instrument.
Critical safety warnings and symbols related to instrument operation and potential hazards.
Explains the static headspace technique and its three basic operations.
Details the process of achieving equilibrium in a closed system for analysis.
Lists the technical specifications of the Versa instrument.
Describes and illustrates the internal and external parts of the Versa instrument.
Details the headspace valves in the Versa system.
Covers the mechanical components of the Versa.
Details the electronic connections for the Versa.
Covers prerequisites and site preparation for installing the Versa.
Details the power requirements for the Versa.
Outlines the necessary gas supply requirements.
Lists the minimum computer specifications for software compatibility.
Guides through the physical and electronic setup of the instrument.
Instructions for establishing communication between the Versa and PC.
Explains how to install the necessary USB drivers.
Details guidelines for proper vial preparation.
Discusses factors affecting the quality of vial seals.
Details the Full Evaporation Technique (FET).
Describes the various operating modes of the Versa.
Guides on configuring the Versa TekLink™2G software.
Covers creating and managing methods and schedules.
Guides on defining method schedules.
Details various software features.
Explains how to run diagnostics for specific components.
Describes the Benchmark test for component testing.
Explains how to access and view history logs.
Details system property configurations.
Lists features and tools for 21 CFR Part 11 compliance.
Details how to manage user accounts and privileges.
Explains how to set user permissions.
Explains how to configure user lockout settings.
Covers data versioning, history logs, and archiving.
Reviews steps for developing robust headspace methods.
Discusses partition coefficient and matrix effects.
Explains the salting-out technique for matrix modification.
Discusses factors influencing sample equilibration.
Discusses gas law parameters affecting headspace.
Details vial pressurization settings.
Provides contact information for support.
Outlines routine maintenance and checks.
Guides on performing a system leak check.
Instructions for upgrading the Versa firmware.
Discusses the importance of preventative maintenance.
Provides troubleshooting guidance for common issues.
Troubleshooting steps for power issues.
Identifies and describes the printed circuit boards.
Addresses heater failure errors and troubleshooting.
Provides instructions for cleaning the carousel.
Shows a detailed plumbing diagram of the Versa system.
Diagram illustrating these operational modes.
Diagram showing the vial raising process.
Diagram illustrating static vial pressure reading.
Diagram showing the pressurization step.
Diagram for pressure equilibration and reading.
Diagram for loop fill and pressure reading.
Diagram illustrating the inject process.
Provides the electrical schematic of the Versa.