SpecificationsCopyright © 2013–2016, Texas Instruments Incorporated
(1) The typical value is the average current for the nominal process corner and junction temperature of 25°C.
(2) The maximum I
CC,
value can be derated
linearly with voltage
by 0.85 mA/MHz for lower operating frequency when f
HCLK
= 2 * f
VCLK
for lower junction temperature by the equation below where T
JK
is the junction temperature in Kelvin and the result is in milliamperes.
126 - 0.005 e
0.024 T
JK
(3) The maximum I
CC,
value can be derated
linearly with voltage
by 0.85 mA/MHz for lower operating frequency
for lower junction temperature by the equation below where T
JK
is the junction temperature in Kelvin and the result is in milliamperes.
126 - 0.005 e
0.024 T
JK
(4) LBIST and PBIST currents are for a short duration, typically less than 10 ms. They are usually ignored for thermal calculations for the
device and the voltage regulator.
5.6 Power Consumption Over Recommended Operating Conditions
PARAMETER TEST CONDITIONS MIN TYP MAX UNIT
I
CC
V
CC
digital supply current (operating mode)
f
VCLK
= f
HCLK
/2; Flash in pipelined mode;
V
CCmax
f
HCLK
= 100 MHz 130
(1)
270
(2)
mA
f
HCLK
= 160 MHz 160
(1)
300
(2)
V
CC
digital supply current (LBIST/PBIST mode)
LBIST/PBIST clock
frequency = 50 MHz
150
(1)
290
(3)(4)
mA
LBIST/PBIST clock
frequency = 80 MHz
215
(1)
360
(3)(4)
LBIST/PBIST clock
frequency = 90 MHz
240
(1)
390
(3)(4)
I
CCIO
V
CCIO
digital supply current (operating mode) No DC load, V
CCmax
15 mA
I
CCAD
V
CCAD
supply current (operating mode)
Single ADC
operational,
V
CCADmax
15
mA
Both ADCs
operational,
V
CCADmax
30
I
CCREFHI
AD
REFHI
supply current (operating mode)
Single ADC
operational,
AD
REFHImax
3
mA
Both ADCs
operational,
AD
REFHImax
6
I
CCP
V
CCP
supply current
Read from 1 bank
and program
another bank,
V
CCPmax
55 mA

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Texas Instruments TMS570LS0714 and is the answer not in the manual?

Texas Instruments TMS570LS0714 Specifications

General IconGeneral
BrandTexas Instruments
ModelTMS570LS0714
CategoryMicrocontrollers
LanguageEnglish

Related product manuals