THRUSH AIRCRAFT, INC – MODEL S2R-G10
AIRCRAFT MAINTENANCE MANUAL
8-12
*NOTE*
Unit must be on to adjust 360
side of gauge.
*NOTE*
The small % scale on analog
control unit Type FA-A will move
in direct relationship with the
remote gauge.
*NOTE*
Hopper loads above 360 gallons
are un-gaugeable.
Also provided with the system are two
hopper-level warning lights: one amber
and one red. They both have a push-to-
test feature and a dimming capability.
The lights are adjusted to come on at
any position (hopper level) that you may
desire by potentiometers located under
pop-off caps on the face of the analog
control unit Type FA-A. The amber light
is adjusted to come on by adjusting Pot
1 labeled set point 1, and the red light is
adjusted to come on by adjusting Pot 2
labeled set point 2.
The amber and red lights can be set at any
position you may desire. Thrush Aircraft
Inc recommends setting the amber light to
come on at 25 gallons, or 8 3/8" from top of
lower stop collar to bottom of floating ball,
and the red light to come on at 6 1/2
gallons, or 2 1/2" from top of lower stop
collar to bottom of floating ball.
INSTRUMENT
TROUBLESHOOTING
Table 8-1, starting on the next page, gives
helpful information to track down the cause
of instrument problems.
Page Effective: 03/26/2010