4.4 Funkcijski blok Krmilna enota za razlike
Nastavitve


nastavitev
Opomba
Primarni senzor (toplo)
T1 do T12
Izbirno
Temperaturni senzor vira toplote
Sekundarni senzor (hladno)
T1 do T12
Izbirno

dT maks. (start)
3 do 40 °C
15 °C
dT maks.
dT min. (stop)
2 do 30 °C
7 °C
dT min.
Min.primarni senzor
0 do 95 °C
65 °C

Maks.sekundarni senzor
15 do 95 °C
15 °C
Maks.temperatura posode

00.00-24.00
00.00-24.00


Postoj
-900 do +900 s
0 s
Pred.(- s) in po (+ s) izhodni zaslon
Sistem 3
Duplex
Sistem 3 (1PHE)
Multiplex
Sistem 3 (2 PHE)
Multiplex
P1= Dt(T1,T2) P2= Dt(T1,T4)
P1= Dt(T1,T2) P2= Dt(T1,T4)
P1= Dt(T1,T2) P2= Dt(T1,T4)
Diff 1 = Px = Dt(Tx,T2)
Ni PHE
Diff 1 = Px = Dt(Tx,T4)
Diff 2 = Py = Dt(Ty,T4)
Sistem 9
Multiplex
Sistem 9 (1PHE)
Multiplex
Sistem 10
Multiplex
Sistem 10
(1PHE)
Multiplex
P1= Dt(T1,T2aliT3) P2=
Dt(T4,T2aliT3)
P1= Dt(T1,T2aliT3) P2=
Dt(T4,T2aliT3)
P1= Dt(T1,T2aliT3) P2=
Dt(T1,T2)
P1= Dt(T1,T2aliT3) P2=
Dt(T1,T2)
P7= Dt(T1 ali T4,T3)
P7= Dt(T1 ali T4,T3)
P5= Dt(T1,T3)
P5= Dt(T1,T3)
Ni PHE
Diff 1 = Px = Dt(Tx,T3)
Ni PHE
Diff 1 = Px = Dt(Tx,T3)
Sistem 11
Multiplex
Sistem11 (1PHE)
Multiplex
Sistem 12
Multiplex
Sistem12
(1PHE)
Multiplex
P1= Dt(T1,T2aliT3aliT7) P2=
Dt(T1,T2)
P1= Dt(T1,T2aliT3aliT7) P2=
Dt(T1,T2)
P1= Dt(T1,T2aliT3aliT7aliT8) P2=
Dt(T1,T2)
P1=
Dt(T1,T2aliT3aliT7aliT8)
P2= Dt(T1,T2)
P5= Dt(T1,T3) P7= Dt(T1,T7)
P5= Dt(T1,T3) P7= Dt(T1,T7)
P5= Dt(T1,T3) P7= Dt(T1,T7) P8=
Dt(T1,T8)
P5= Dt(T1,T3) P7=
Dt(T1,T7) P8= Dt(T1,T8)
Ni PHE
Diff 1 = Px = Dt(Tx,T7)
Ni PHE
Diff 1 = Px = Dt(Tx,T8)