26-4
26 SPECIFICATIONS
Storage temperature range: -20 to 65°C
Size: 94 (W) X 102 (D) X 36 (H) mm
Weight: about 170g
General
Display unit: LCD graphic display, 192 dots X 80 dots
ES-62: 1 LCD graphic display on each face with illuminator
ES-65: 1 LCD graphic display with illuminator
Operation panel (keyboard): 25 keys (soft function, operations, power on, light) with
illuminator
Laser-pointer function: Provided On/Off (selectable)
Internal memory: 1MB (about 10,000 points)
Sensitivity of levels:
Circular level: 10'/2 mm
Electronic Circular levels:
Graphic display range 6’ (inner circle)
Digital display range ±6’ 30"
Optical plummet:
Image: Erect
Magnification: 3X
Minimum focus: 0.3 m
Laser plummet (option):
Signal source: Red laser diode 635 ±10nm (Class 2 IEC60825-1 Ed.
3.0:2014/FDA CDRH 21CFR Part 1040.10 and 1040.11
(Complies with FDA performance standards for laser
products except for deviations pursuant to Laser Notice
No.50, dated June 24, 2007.))
Beam accuracy: 1mm or less (when tripod head height is 1.3m).
Spot diameter: ø3mm or less
Brightness control: 5 levels
Auto power-off Provided (power cut off after 5 minutes)
Operating temperature (no condensation): -20 to 60 °C (-4 to 140 °F)
*9
Storage temperature range (no condensation):-30 to 70 °C (-22 to 158 °F)
Dust and water resistance: IP66 (IEC 60529: 2001)
Instrument height: 192.5 mm from tribrach mounting surface
236mm +5/-3mm from tribrach bottom
Size (with handle):
ES-62: 191 (W) X 181 (D) X 348 (H) mm
ES-65: 191 (W) X 174 (D) X 348 (H) mm
Weight (with handle and battery): 5.4kg (11.9lb)
*9: No direct sunlight for using high temparatures of 50 to 60 °C (122 to 140 °F).