Configuring the Receiver
PerformingaFactoryReset(ClearingtheNV RAM )
45
P/N:100160801
Figure22:ResettheReceiver
6. ClickYes.
Performing a Factory Reset (Clearing the NVRAM)
ThereceiversNonVolatileRandomAccessMemory(NVRAM)holdsdatarequiredforsatellitetracking,suchasephemerisdata
andreceiverposition.TheNVRAMalsokeepsthecurrentreceiver ssettings,suchasactiveantennainput,elevationmasksand
recordinginterval,andinformationaboutthereceiversinternalfilesystem.Clearingthereceiver sNVRAM
restoresthe
receiver sfactorydefaultsettings.
AlthoughclearingtheNVRAMisnotrecommendedasacommonpractice,therearetim eswhenitcaneliminatecommunication
ortrackingproblems.
AfterclearingtheNVRAM,thereceiverrequirestimetocollectnewephemeridesandalmanacs(around15minutes).
ClearingtheNVRAMwillnotdelete
anyfilesalreadyrecordedinthereceiversmemory,andtheNVRAMkeepsinformation
aboutthereceiverfilesystem.