EasyManuals Logo

Toro Dingo TX 413 User Manual

Toro Dingo TX 413
244 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #64 background imageLoading...
Page #64 background image
TX 413 Service Manual
6-7
HYDRAULIC SYSTEM
Rev. 000
Figure 107 DSC-0861
6. Remove the upper end of the inlet hydraulic line
at the T-fitting adapter, (page 6-2, Ref. 6), located
on the lower hydrostatic pump (Fig. 107, top
view).
Figure 108 DSC-0863
8. Loosen and remove the hydraulic inlet line, (page
6-2, ref 7), located on the back side of the upper
hydrostatic pump (Fig. 109).
Figure 109 DSC-0864
7. On the lower side of the T-fitting adapter, remove
the hydraulic inlet line, (page 6-2, Ref. 7), from
the lower hydrostatic pump that runs to the upper
hydrostatic pump (Fig. 108, top view).
9. Disconnect the hydrostatic case drain line from
the T-fitting adapter, (page 6-2, Ref. 5), at the
lower hydrostatic pump (Fig. 110, rear view).
Figure 110 DSC-0869

Table of Contents

Other manuals for Toro Dingo TX 413

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Toro Dingo TX 413 and is the answer not in the manual?

Toro Dingo TX 413 Specifications

General IconGeneral
BrandToro
ModelDingo TX 413
CategoryCompact Loader
LanguageEnglish

Related product manuals