6-7
HYDRAULIC SYSTEM
Rev. 000
Figure 107 DSC-0861
6. Remove the upper end of the inlet hydraulic line
at the T-fitting adapter, (page 6-2, Ref. 6), located
on the lower hydrostatic pump (Fig. 107, top
view).
Figure 108 DSC-0863
8. Loosen and remove the hydraulic inlet line, (page
6-2, ref 7), located on the back side of the upper
hydrostatic pump (Fig. 109).
Figure 109 DSC-0864
7. On the lower side of the T-fitting adapter, remove
the hydraulic inlet line, (page 6-2, Ref. 7), from
the lower hydrostatic pump that runs to the upper
hydrostatic pump (Fig. 108, top view).
9. Disconnect the hydrostatic case drain line from
the T-fitting adapter, (page 6-2, Ref. 5), at the
lower hydrostatic pump (Fig. 110, rear view).
Figure 110 DSC-0869