EasyManua.ls Logo

Toshiba E-STUDIO2006 - Page 529

Toshiba E-STUDIO2006
730 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
05/08 Mode Element
Sub
element
Item Subitem Code
Sub-
code
Details
Default
value
Acceptabl
e value
SRAM Contents
Proce
dure
20L
/
23L /
25L
20H
/
23H /
25H
05 Adjustment
mode
Scanner Scanner 3228 - LED (G2) current
effective value setting
(black scanning)
60 0-255 M It will become bright if a value is enlarged.
The light is put out by 0.
1
YY
05 Adjustment
mode
Scanner Scanner 3229 - LED (B2) current
effective value setting
(black scanning)
60 0-255 M It will become bright if a value is enlarged.
The light is put out by 0.
1
YY
05 Adjustment
mode
Scanner Scanner 3230 - Threshold adjustment
of the 1st document
size detection
128 0-255 M 1
-Y
05 Adjustment
mode
Scanner Scanner 3231 - Threshold adjustment
of the 2nd document
size detection
128 0-255 M 1
-Y
05 Adjustment
mode
Scanner Scanner 3233 - Document size
detection adjustment
(Primary scanning
direction
)
128 0-255 M 1
-Y
05 Adjustment
mode
Scanner Scanner 3234 - Carriage standby
position adjustment of
document size
detection
200 0-255 M 255: 25.5mm from a reading starting position
100: 10.0mm from a reading starting position
0: 0.0mm from a reading starting position
1
-Y
05 Adjustment
mode
Scanner Scanner 3235 - Detection operating
time adjustment of 1st
document size
detection
15 0-255 M Adjustment of the time for detective start.
255:The minimum operating time plus 2040ms
0:The minimum operating time
1
-Y
05 Adjustment
mode
Scanner Scanner 3236 - Detection operation
lamp lighting time
adjustment of 1st
document size
detection
128 0-255 M Adjustment of the lamp lighting time.
255: The minimum lamp lighting time plus 2040ms
0: The minimum lamp lighting time
1
-Y
05 Adjustment
mode
Scanner Scanner 3239 - LED (R2) current
effective value setting
(clolor scanning)
128 0-255 M It will become bright if a value is enlarged.
The light is put out by 0.
1
YY
05 Adjustment
mode
Scanner Scanner 3240 - LED (G2) current
effective value setting
(clolor scanning)
128 0-255 M It will become bright if a value is enlarged.
The light is put out by 0.
1
YY
05 Adjustment
mode
Scanner Scanner 3241 - LED (B2) current
effective value setting
(clolor scanning)
128 0-255 M It will become bright if a value is enlarged.
The light is put out by 0.
1
YY