ERROR CODE AND SELF-DIAGNOSTIC MODE
2 - 196
9739 Mainte-
nance
Remote service
Toner-end notification
ALL 0
<0-2>
SYS 0: RDMS toner empty
notified immediately
1: RDMS toner empty
notified once a day
2: RDMS toner empty
not notified
1
9819 General STAGE SSL ALL 1
<0-1>
SYS When remote scanning
is performed, the SSL
communication is car-
ried out.
0: Disabled
1: Enabled (SSL com-
munication)
1
9822 General STAGE SSL port number ALL 20443
<0-
65535>
SYS When remote scanning
is performed using SSL
communication, the
SSL port number is set.
1
9828 General Remote scanning mode ALL 0
<0-1>
SYS 0: Batch
1: Sequential
1
9829 General Department management
limitation setting
ALL 0
<0-3>
SYS Decide the default limi-
tation setting when the
new department code is
created.
0: No limit
1: Limited only in the
black mode
2: Limited in the color
mode
3: Limited in the black/
color mode
1
9847 Finisher Hole punching setting ALL 0
<0-1>
SYS 0: Invalid
1: Valid
1
9880 General Total counter transmission
date setting (2)
ALL 0
<0-31>
SYS 0 to 31 1
9881 General Day of total counter data
transmission
ALL 0
<0-127>
- 1 byte 00000000(0)-
01111111(127)
From the 2nd bit -
Sunday, Monday,
Tuesday, Wednesday,
Thursday, Friday,
Saturday
1
9882 General Display mode of the used
capacity on the e-Filing
administrator page
ALL 1
<0-1>
SYS 0: All files search
mode
1: Performance priority
mode
1
9885 General New/Old FROM identifica-
tion
ALL -
<-1-1>
- 0: Old FROM
1: New FROM
-1: Error
2
9886 Scanner Decimal point indication for
Enhanced Scan Template
SCN EUR: 0
UC: 1
JPN: 1
<0-1>
SYS 0: Comma
1: Period
1
9888 Scanner Permission setting for
changing the scan parame-
ter when recalling an
extension
SCN 0
<0-1>
SYS 0: Prohibited
1: Accepted
1
Setting mode (08)
Code
Classifi-
cation
Items
Func-
tion
Default
<Accept-
able
value>
RAM Contents
Pro-
cedur
e

Table of Contents