OPERATOR’S MANUAL
series Robot Controller
(c) Step 3: Input through EXE key.
Make sure that your entry is correct, and press the EXE key. Then the
specified file name is displayed in the execution file display field on the 1st
line at the same time that [RUN] is displayed in the menu to indicate that you
can start a test operation.
M O D E : T E A C H I N G / C O N T T E S T P R O
L :
O : 20%
M : F REE
S : S TOP
R E SET
E D I T D E D I T S E L R U N F I L E
>
(3) Cautions
Once the execution file has been selected, it remains effective until another
file is selected.
If a compile error has occurred, however, selection of the execution file is
canceled.
When another file has been selected, the execution environment of automatic
operation is reset.
To reset the execution environment without changing the execution file, press
the NEXT key followed by [RESET] and [PROG].
STE 80720
– 6-5