OPERATOR’S MANUAL
series Robot Controller
P R G R A M . N A M C : 1 L : 5
P R O G R A M T E S T
S P E E D = 5 0
M O V E A
M O V E B
M O V E C
N O S A V C O P Y C U T P A S T E >
(d) Step 4: Copy of specified range.
Press [COPY], and the contents of the specified range of blocks are saved in
the buffer. The contents thus saved can be pasted at any desired position
by pressing [PASTE].
P R G R A M . N A M C : 1 L : 5
P R O G R A M T E S T
S P E E D = 5 0
M O V E A
M O V E B
M O V E C
N O S A V C O P Y C U T P A S T E >
If the memory becomes full during copying, a warning saying "No more space
in cut buffer" is displayed.
P R G R A M . N A M C : 1 L : 4
M O V E A
M O V E B
M O V E C
M O V E D
M O V E E
N o m o r e i n c u t b u f f e r
N O S A V C O P Y C U T P A S T E >
(3) Caution
If the memory becomes full during copying, the copying is not possible.
STE 80720
– 4-23