Operation
If a malfunction occurs
07/2019 244156V03_EN 57
Display shows:
ERR 1
Infeed cover not closed Close the infeed cover
Safety switch is maladjusted or
defective
Call service department.
Display shows:
ERR 2
Front door not locked Lock front door
Safety switch is maladjusted or
defective
Call service department.
Display shows:
ERR 5
Blade motor overheated
(thermal switch)
Let the motor cool down
Display shows:
ERR 9, 10, 12, 13, 24-26, 32
Controller error Switch off the machine
Call service department
Display shows:
ERR 11
Knife guard on the machine during
machine operation
Remove knife guard
Display shows:
ERR 16, 33-34
Brake defective Switch off the machine
Call service department
Display shows:
ERR 23
The measurement object used for
the calibration process is too short
Repeat calibration process with
longer measurement object.
Display shows:
ERR 31
Product feed holder cannot move to
the rear position
Remove product behind the product
feed holder.
The slice thickness is uneven The product is too soft or too fresh Let the product stand for a few
hours
Blade is blunt Replace the blade
The product is not held tight by the
product feed holder
Fasten the product feed holder to
the product
The product feed holder does not
advance
The feed motor is overheated Let the feed motor cool down
The slices are not clean Blade is blunt Replace the blade
The blade's silicone layer is dam-
aged
Replace the blade
The blade cutting edge is smeared Clean the blade
The following is shown on the dis-
play
A START/STOP button has been
pressed immediately after ending
the cutting process without previ-
ously removing the product.
Open feeding lid, remove product
and close feeding lid.
The following is shown on the dis-
play
The removal chamber has not been
folded up
The removal chamber is not in its
home position
Slice support is blocked
Fold up removal chamber until in
locking position, see page 31
Fold removal chamber down and up
again until in locking position, see
pages 27+31
Remove product residues from
removal chute
Malfunction Cause Remedy