1.7 Sentro Sensing Modules
Plug-in pre-calibrated eModules and rModules with standardised output data.
Each eModule and rModule stores all the necessary data about its type,
identification, sensing range and specific calibration. This data is automatically
recognised by Sentro 8 Sensorstation when the eModule or rModule is
plugged into the module bay
The eModule and rModule are pre-calibrated so they can be replaced at any
time with a replacement sensing module - usually of the same type, but an
alternative may be inserted if required
User configurable coding slots at each module bay can be individually
configured using coding stops to prevent invalid sensing module combinations
The eModule and rModule will identify itself when plugged into the module
bay, auto configuration will take place and the sensing module type will display
on the LCD screen
All Sentro eModules and rModules have two output alarm signals for General
alarm and High alarm. Default values are entered during manufacture and
these can be changed to preferred values
There are two types of Sentro sensing module:
Sentro eModule
Integral Gas Sensor
Sentro rModule
Terminals for Connecting Remote Sensors
www.trolex.com