ENABLE A DISPLAYED VALUE. To enable a displayed target
value, press the number key that matches the number beside the
target value on the Target Value menu. The gauge will enable the
target value and return to the Target Value menu. Return to the
Ready screen by pressing the
〈ESC〉 key.
STORE A NEW VALUE. To store a new target value, press 〈5〉
New at the Target Value menu. At the prompt, use the number keys
to enter the target value. Press the
〈ENTER〉 key.
The gauge displays the value entered and asks if the operator wants
to store the value. To store the value, press the
〈YES〉 key. Pressing
the
〈NO〉 key allows the operator to use the value now without
storing it for later use.
If the operator presses the 〈YES〉 key, the gauge can store the value
in one of four memory cells. Storing a new value in a cell erases the
old value. At the Select memory cell prompt, use the number
keys to store the value. This will replace any stored values that were
previously associated with the memory cell.
The gauge will enable the target value and return to the Target
menu. Return to the Ready screen by pressing the 〈ESC〉 key.
DISABLE THE TARGET VALUE. To disable the target value,
press
〈6〉 Disable at the Target Value menu. The gauge will disable
the target value and return to the Target menu. Return to the Ready
screen by pressing the
〈ESC〉 key.
NOTE
The 3450 gauge can be used with the target value
disabled. In this case, no percent compaction value will
be displayed.