Version 1
60
Ultraprobe
®
10,000 Specifications
Construction
Hand-held pistol type made with coated aluminum and ABS
plastic
Circuitry
Solid State Analog and SMD Digital Circuitry with tempera-
turecompensation and true RMS conversion
Frequency Range
20 KHz to 100 KHz (tunable in 1 KHz increments)
Response Time
< 10 ms
Display
64x128 LCD with LED Backlight
Memory
400 storage locations
Battery
Lithium NIMH Rechargeable
Operating Temperature
0°C to 50°C (32°F to 122°F)
Outputs
Calibrated heterodyned output, decibel (dB)
frequency, RS-232 data output
Probes
Trisonic Scanning Module and Stethoscope Module, Long
Range
Module and RAS/RAM
Headset
Deluxe noise attenuating headphones For hard hat use
Indicators
dB, Frequency, Battery Status and 16 Segment Bar Graph
Sensitivity
Detects 0.127 mm (0.005”) diameter leak @ 0.34 bar (5 psi) at
a
distance of 15.24 m (50 ft.)
Threshold*
1 x 10
2
std. cc/sec to 1 x 10
3
std. cc/sec.
Dimensions
Complete kit in Zero Halliburton aluminum carrying case 55 x
47 x 20 cm (21.5” x 18.5” x 8”)
Weight
Pistol Unit: 1.1 kg (2.35 lbs.) Complete carrying case: 8.6 kg (19
lbs)
Warranty
1-year parts/labor standard
5 years with returned, completed warranty registration
Display Modes
Real Time, Snap Shot, Peak Hold, Storage Display and
Application Specific
* Depends on leak configuration