60
Ultraprobe
®
10,000 Specifications
Construction
Hand-held pistol type made with coated aluminum and ABS
plastic
Circuitry
Solid State Analog and SMD Digital Circuitry with tempera-
turecompensation and true RMS conversion
Frequency Range
20 KHz to 100 KHz (tunable in 1 KHz increments)
Response Time
< 10 ms
Display
64x128 LCD with LED Backlight
Memory
400 storage locations
Battery
Lithium NIMH Rechargeable
Operating Temperature
0°C to 50°C (32°F to 122°F)
Outputs
Calibrated heterodyned output, decibel (dB)
frequency, RS-232 data output
Probes
Trisonic Scanning Module and Stethoscope Module, Long
Range
Module and RAS/RAM
Headset
Deluxe noise attenuating headphones For hard hat use
Indicators
dB, Frequency, Battery Status and 16 Segment Bar Graph
Sensitivity
Detects 0.127 mm (0.005”) diameter leak @ 0.34 bar (5 psi) at
a
distance of 15.24 m (50 ft.)
Threshold*
1 x 10
2
std. cc/sec to 1 x 10
3
std. cc/sec.
Dimensions
Complete kit in Zero Halliburton aluminum carrying case 55 x
47 x 20 cm (21.5” x 18.5” x 8”)
Weight
Pistol Unit: 1.1 kg (2.35 lbs.) Complete carrying case: 8.6 kg (19
lbs)
Warranty
1-year parts/labor standard
5 years with returned, completed warranty registration
Display Modes
Real Time, Snap Shot, Peak Hold, Storage Display and
Application Specific
* Depends on leak configuration

Table of Contents

Other manuals for UE Systems ULTRAPROBE 10000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the UE Systems ULTRAPROBE 10000 and is the answer not in the manual?

UE Systems ULTRAPROBE 10000 Specifications

General IconGeneral
BrandUE Systems
ModelULTRAPROBE 10000
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals