Communication module R-208
Radio frequency, EAC markets only 869 MHz
Transmitter duty cycle <1%
Receiver class 2
Connection terminals RJ45 Ethernet connection (10/100BaseT)
Room controller X-245
IP IP20, class II (IP: degree of inaccessibility to active parts of the product
and degree of water)
Max. ambient RH (relative humidity) 85% at 20 °C
CE marking
ERP (with communication module and the Uponor Smatrix PULSE app) VIII
ERP (without communication module and the Uponor Smatrix PULSE
app)
IV
Low voltage tests EN 60730-1* and EN 60730-2-1**
EMC (electromagnetic compatibility requirements) tests EN 60730-1
Power supply 230 V AC +10/-15%, 50 Hz or 60 Hz
Internal fuse T5 F3.15AL 250 V, 5x20 3.15A quick acting
Rated impulse voltage 2.5 kV, OVC II
Pollution degree 2
Software class A
Operating temperature 0 °C to +45 °C
Storage temperature -20 °C to +70 °C
Maximum consumption 45 W
Pump and boiler relay outputs 230 V AC +10/-15%, 250 V AC 8 A maximum
Micro gap, normally open
General purpose input (GPI) Only dry contact
Valve outputs 24 V AC, 0.2 A average, 0.4 A peak
Power connection 1 m flexible cord, with europlug (except UK), which is connected to the
controller
Connection terminals for power, pump, GPI and boiler Up to 4.0 mm² solid, or 2.5 mm² flexible with ferrules
Connection terminals for bus communication 0.5 mm² to 2.5 mm²
Connection terminals for valve outputs 0.2 mm² to 1.5 mm²
*) EN 60730-1 Automatic electrical controls for household and similar
use -- Part 1: General requirements
**) EN 60730-2-1 Automatic electrical controls for household and
similar use -- Part 2-1: Particular requirements for electrical controls
for electrical household appliances
***) EN 60730-2-9 Automatic electrical controls for household and
similar use -- Part 2-9: Particular requirements for temperature
sensing controls
Usable in all Europe
Declaration of conformity:
We hereby declare under our own responsibility that products dealt with
by these instructions satisfy all essential demands linked to the
information stated in the Safety instruction booklet.
15.2 Cable specifications
Cables Standard cable length Maximum cable length Wire gauge
Cable from room controller to
communication module
2 m 5 m CAT.5e or CAT.6, RJ 45 connector
Cable from room controller to
actuator
0.75 m 20 m Room controller: 0.2 mm² to 1.5
mm²
External sensor cable to thermostat 5 m 5 m 0.6 mm²
Floor sensor cable to thermostat 5 m 5 m 0.75 mm²
Outdoor sensor cable to thermostat - 5 m Twisted pair
Cable from relay switch to room
controller GPI input
2 m 20 m Room controller: Up to 4.0 mm²
solid, or 2.5 mm² flexible with
ferrules
Relay: 1.0 mm² to 4.0 mm²
Uponor Smatrix Base PULSE
|
Installation and operation manual
|
91

Table of Contents

Other manuals for Uponor Smatrix Base PULSE

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Uponor Smatrix Base PULSE and is the answer not in the manual?

Uponor Smatrix Base PULSE Specifications

General IconGeneral
BrandUponor
ModelSmatrix Base PULSE
CategoryController
LanguageEnglish

Related product manuals