5. Unregister the channel
5 s
SI0000156
Press the < and > buttons simultaneously until the LED for the
selected channel starts flashing red (about 5 seconds).
6. Exit registration mode
3 s
SI0000078
Press and hold the OK button on the room controller until the green
LEDs turn off to end registration and return to run mode.
Unregister all room controller channels
1. Enter registration mode
3 s
SI0000065
Press and hold the OK button on the room controller until the LED for
channel 1 (or the first unregistered channel) flashes red.
2. Unregister all channels
10 s
SI0000160
Press the < and > buttons simultaneously until the LEDs for all
channels except one turn off (about 10 seconds). The one remaining
flashes red.
3. Exit registration mode
3 s
SI0000078
Press and hold the OK button on the room controller until the green
LEDs turn off to end registration and return to run mode.
10.8
Update room controller
software (optional)
The room controller software can be updated using the Uponor
Smatrix PULSE app (requires communication module and connection
to Uponor cloud services).