6.3 Uponor Smatrix Base T-144
Placement of thermostat
• Select an indoor wall and a position 1.3 m to 1.5 m above the
floor.
• Ensure that the thermostat is away from direct sunlight.
• Ensure that the thermostat will not be heated through the wall by
sunshine.
• Ensure that the thermostat is away from any source of heat, for
example television set, electronic equipment, fireplace,
spotlights, and so on.
• Ensure that the thermostat is away from any source of humidity
and water splashes (IP20).
Label thermostat
Label the thermostat, where suitable, with the channel numbers they
are to control, for example, #02, #03. For a system with several room
controllers, add the ID of each room controller, for example, 1.02,
1.03, 2.02, 2.03.
Connect communication cable to thermostat
1. Insert the four wires into the connectors marked (A,B, + and -)
on the thermostat.
2. Tighten the screws fixing the wires in the connector.
Attach thermostat to the wall
1. Insert the wall bracket into a wall box and fasten it with screws.
Make sure the communication wires is connected.
2. Attach and hold the wall frame into place.
3. Fasten the wall frame with the two screws and plastic insert.
4. Attach the transparent LED-ring.
5. Attach the dial.
Register thermostat to room controller
1. Enter registration mode
Press and hold the OK button on the room controller until the LED for
channel 1 (or the first unregistered channel) flashes red.
Uponor Smatrix Base PULSE
|
Installation and operation manual
|
41