07 Cooling allowed
In this menu it is set whether cooling is allowed in the room or not.
This menu is not visible if a communication module is connected to
the system. The setting is then available in the Uponor Smatrix
PULSE app.
See Change settings, Page 76, for how to change the setting.
Uponor Smatrix Base T-146
Display text Description
Yes Shows the cooling demand icon
No Hides the cooling demand icon
Uponor Smatrix Base T-148
Display text Description
Yes Shows the cooling demand icon
No Hides the cooling demand icon
Uponor Smatrix Base T-149
Symbol Description
Shows the cooling demand icon
Hides the cooling demand icon
08 Display unit
In this menu temperature display unit is set.
See Change settings, Page 76, for how to change the setting.
Uponor Smatrix Base T-146
Display text Description
DEg ˚C Degrees Celsius
DEg ˚F Degrees Fahrenheit
Uponor Smatrix Base T-148
Display text Description
DEg ˚C Degrees Celsius
DEg ˚F Degrees Fahrenheit
Uponor Smatrix Base T-149
Symbol Description
Degrees Celsius
Degrees Fahrenheit
10 Time and date (T-148 only)
In this menu time and date is set. This setting is required to utilise
scheduling programs for this thermostat.
If another programmable digital thermostat is registered to the room
controller (with a lower channel number), or if the Uponor Smatrix
PULSE app is used, they will push the set time and date to the
thermostat. Then only the 12/24 h setting is available.
Use buttons - or + to change the value. Press the OK button to set
the value and move to the next editable value.
Values will be set in the following order.
1. Hours
2. Minutes
3. 12/24h mode
4. Day of the week (1 = Monday, 7 = Sunday)
5. Day of the month
6. Month
7. Year
See Change settings, Page 76, for how to change the setting.
11 Room temperature calibration
Default: 0.0 ˚C
Setting range: -6.0 – 6.0 ˚C, 0.1 ˚C increments
In this menu the room temperature shown in the thermostat display
can be calibrated.
See Change settings, Page 76, for how to change the setting.
12 Invert screen (T-149 only)
In this menu the colour in the display can be inverted.
See Change settings, Page 76, for how to change the setting.
12.7 Factory reset
Note
Do not factory reset the thermostat if not absolutely
needed.
Note
A factory reset removes the registration data from the
thermostat.
Factory reset sets all parameter values to default settings.
80
|
Uponor Smatrix Base PULSE
|
Installation and operation manual

Table of Contents

Other manuals for Uponor Smatrix Base PULSE

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Uponor Smatrix Base PULSE and is the answer not in the manual?

Uponor Smatrix Base PULSE Specifications

General IconGeneral
BrandUponor
ModelSmatrix Base PULSE
CategoryController
LanguageEnglish

Related product manuals