- 35 -
2 - TECHNICAL DATA
AYROS
800-230V
AYROS
1200-230V
AYROS
1200-120V
Gate maximum weight 800 kg 1200 kg 1200 kg
Power supply 230Vac / 50Hz 230Vac / 50Hz 120Vac / 60Hz
Maximum power 500 W 600 W 600 W
Full load current 2 A 2,6 A 4,3 A
Running capacitor 10 μF 12 μF 36 μF
Start off capacitor 18 μF 25 μF 75 μF
Gate maximum speed 0,16 m/s 0,16 m/s 0,18 m/s
Maximum thrust 670 N 950 N 950 N
Duty cicle 30 % 30 % 30 %
Pinion M4 - Z18 M4 - Z18 M4 - Z18
Operation temperature -20 ÷ +55 °C -20 ÷ +55 °C -20 ÷ +55 °C
Weight 15 kg 16 kg 16 kg
Protection IP44 IP44 IP44
Maximum load on 24 Vdc attachments 10 W 10 W 10 W
Protection fuses 10 A 10 A 15 A